Emergency Exit Lights are an essential part of the fire safety plan for any building. A businesses fire safety plan, including the exit lights, must conform with the latest standards that apply to the building and must be serviced and maintained according to those regulations as well. This can help ensure the safety of employees and customers if the building does catch on fire and can help save lives.

How Do Emergency Exit Lights Save Lives?

When there is a fire in the building, the lights may go out. Even if it is daytime and there are plenty of windows in the building, it can still be impossible for a person to see where they are going because of the smoke building up in the rooms. This can happen extremely quickly and some of the people in the building may not be able to make their way to the exit doors without additional help. This additional help should be available in the form of Emergency Lights. Exit lights and other lighting in the building that is powered by an alternate source can help a person find their way to the exit and prevent death or serious injuries from smoke inhalation or the fire itself.

Building Codes and Regulations that Apply for Emergency Exit Lights

Businesses will need to follow the Building Code of Australia (BCA) Section E Part E4 and Australian Standard AS2293.1. There may be more stringent requirements for buildings built after the first of July, 1994. This includes all class 6 buildings over 100 square meters that were built after this date.

Where Must Emergency Exit Lights be Installed?

The regulations mentioned above dictate where the exit lights must be installed for the benefit of employees and customers. The requirements will differ based on the class of the building as well as the size of the building. Some of the requirements include the following though a business will always want to check with a professional to ensure they have the proper Emergency Exit Lighting for their building.

  • In every fire-isolated stairway, ramp or passageway.
  • For class 5, 6, 7 8, or 9, in a story that has a floor area more than 300 square meters for every passageway, corridor or hallway that is part of the path to an exit, in any room that has a floor area of more than 100 square meters that doesn’t have an opening to a space that has emergency lighting, and in any room that has an area of more than 300 square meters.
  • In the passageway, corridor, or hallway more than six meters from the entrance of the doorway to a sole-occupancy unit in a class two or three building which opens to a fire isolated stairway, ramp or passageway, an external stairway serving instead of a fire-isolated stairway, an external balcony leading to a fire-isolated stairway, or an open space or road.
  • In all required non-fire-isolated stairways.

Ongoing Maintenance of Emergency Exit Lights

All fire safety equipment, including exit signs and lighting, must be maintained and serviced on a regular basis. Most of the time, it’s required for them to be serviced every six months. The business must also keep records of the inspections and any maintenance that is performed.

It’s essential for any business to ensure they are in compliance with the rules and regulations for exit signs and lighting within their building. This can help ensure everyone can make it out of the building safely if there is an emergency situation and can help save lives. A FCF Fire and Electrical professional will be able to explain the regulations as they apply to a specific business or type of building and can help ensure the business is complying with all applicable regulations. Contact Us Today